• slider-image
    IDENTIFICATION AND SECURITY
    PROFESSIONAL ACCESS CONTROL SYSTEMS

SYSTEM ARCHITECTURE

image

NODER Access Control System is designed as a server -clienct architecture. The server enables the configuration, management and information from distributed controllers in the system. ACS is designed based on ethernet controllers communicate with the server through a secure protocol TCP/IP network using SSL or AES encryption

image

Each of the NODER EE12 access controllers is a fully autonomous device based on a mini-computer working under the Linux operating system. The periphery (inputs, outputs, readers) is controlled by an additional microprocessor. The controller saves codes, schedules and access levels, recent events and other necessary information needed for independent work. In the absence of communication with the server, the controller still allows access to protected rooms to authorized users and the recording of events in the built-in memory. The decision to allow access to the protected room (after reading the employee's card) is taken by the controller (unless otherwise specified), which ensures an immediate reaction of the actuators (release of the door lock). The operation of the controller is independent of the availability and quality of communication with the server. After restoring the connection to the server, all saved events in the controller are automatically downloaded by the server and saved in the system database. This allows you to store events for any period of time, limited only by the capacity of hard disks installed in the server.

FULL SUPPORT FOR DIFFERENT TYPES OF PASSAGES

image

Connecting the access control equipment to the NODER EE12 controller allows to:

  • flexible settings for staff and guests defining time constraints and possible transition direction,
  • recording of all events in the system and full reporting that can be used to settle work time or for other purposes,
  • registration of passages made available by an authorized security guard, record of time and direction of passage,
  • remote opening of locked doors for one-way passage or unblocking, for example, a turnstile in a given direction for a long time,
  • automatic releasing of the turnstile in case of fire,
  • remote blocking or unblocking of the transition from the system client,
  • possibility of confirming the access rights to a chosen room by a security guard,
  • various identification modes: carat, PIN, card or PIN, card and PIN,
  • AntiPassBack global and local,

SOFTWARE MANAGEMENT

image

The software of the NODER system enables integration of the other security systems such as Intruder Alarm Systems (e.q. Satel, Galaxy, DSC, Paradox etc.) or fire alarm systems (e.q. Polon-Alfa, Schrack, Bosch, Esser, Siemens, etc.). Software management enables full configuration, status monitoring and management of access control passages. Software updates are free of charge. The controller's firmware can be updated from the server without disconnecting it from the connected devices via the communication line.

Functionalities that are implemented through the server:

  • Supervision over connections with controllers and the state of connected peripheries,
  • Configuration of controllers and access control transitions,
  • Monitoring of statuses and events in the system with the accuracy of a single door,
    • accepted or rejected access,
    • entrance or exit,
    • waiting for passage,
    • no passage after using authirized card,
    • operating mode (normal, unlocked reader),
    • strain,
    • too long holding the door,
    • switching to battery operation,
    • sabotage of the controller’s casing.
  • Control from the map level (view of the building):
    • one-time passage opening,
    • permanent unlocking the passage,
    • permission to access (in the case of working in dual access mode – with the operator’s confirmation),
    • possibility of individual control of controller outputs,
    • displaying the image from the camera observing the passage after clicking the chosen camera icon on the map,
    • automatic display of a camera or several cameras assigned to a chosen passage after clicking the door icon on the map.
  • Access Control Panel:
    • creating rules of permissions and schedules,
    • adding users and granting permissions,
    • automatic filling the field with the card number in cooperation with a dedicated USB reader or from any reader in the system,
    • data update, blocking or deleting users,
    • creating and granting rights for user groups (departments),
    • assigning photo to a user (from a file or by capturing a picture from any camera in the system),
    • quick cards printing using previously prepared templates,
    • quick search for users, schedules, access levels,
    • ability to create any user types which will contain various, individually created data fields (Employees, Guests, Customers, etc.),
    • ability to restrict operator’s access to selected data user (invisible, read, read and record),
    • granting operators the ability to create, delete and modify users / departments,
    • creating users with the Antipassback function,
    • locating users
  • Ability to import or export users to other systems (txt, csv, Excel, database file).
  • Cooperation with the "Event Manager" module enabling eg photo identification or access in dual mode. Examples of action scenarios:
    • Tracking events, related only to specific access control passage. The security guard tracks events only from the passages he is responsible for, at the sime time only events that are relate to selected passages are displayed on the screen.
    • Photoidentifiation. When the security guard walks nerby the passage, on the screen displayes a picture of a passing employee, connected with his indentifier. The security guard approves access via the software interface or by pressing the door open buton connected directly to the controller.
    • Photo- and videoidentyfication. When the security guard is far from the access point. While identifying employees (card reading), not only their photographs, but also videos from the appropriate camera appear on the screen of the security guard. No matter how far away the work station is from the passage, the security guard can grant access after comparing photographs and videos.
    • Displaying special information about employees. While identyfiying an employee, any information stored in his file can be displayed on the security guard’s screen. For example next to basic information such as photo, name, position etc. on the screen might be an information if the employee can bring a laptop with him.
    • A central point of tracking of disturbing events, whcich is displaying the status of access points on the map and automatically displaying the video from the corresponding camera. In a central supervisory position, only disturbing events ar usually dispalyed, such as burglary or changing the status of connection with controllers etc. As their number is small, therefore the station may serve at the same time more passages. All events are real-time displayed on the map with the video from a specific camera.

ADDITIONAL SYSTEM FUNCTIONALITY

image
  • integration of Intruder Alarm Systems
  • fire protection integration
  • CCTV integration
  • video analysis with inteligent search
  • license plates recognition
  • face recognition

GUARD ROUTE SYSTEM

Tracking and reporting security guards attendance in designated points

image

By using the Axxon Intellect system as the Noder Access Control management system, we have the possibility to tracking security guards attendance in designated points of building or area. The module can also be used to monitor the presence of service teams or other operating services in remote locations.

Principle of operation

The configured guard route consists of a Mifare DESFire Noder RFID readers located on the object, which are part of the access control system operating on the site. We can configure dedicated card for a given route or a card of any user of the access control system. Guard route starts automatically when the card is applied to the first reader on a configured guard route or according to a previously configured schedule, which is signalled graphically and by sound on the Axxon Intellect client station. Security guard has a designated time to reach the route registration point, which is determined independently for each of them. If card is not read at this time, alarm will be generated at the client station and it has to be verified, classified and confirmed by the system operator.

Visualisation

All points of the route are visualized on the map of the object/building, and during the active tour they show their current status (point inactive, point active, whether it has been counted in the tour, time remaining to reach the point, reader failure). Clicking on a given point displays the cameras assigned to them from CCTV system of the object. Up to four cameras can be assigned to each of the points, which will be automatically displayed to the operator after the card has been applied to the given route reader by the guard or in case of a route alarm. You can use any camera connected to any server in the Axxon’s system. In the case of PTZ cameras, you can also define a preset that will be called in the these situations.

Reporting

All events are saved and correlated with the video archive. It is also possible to generate reports on the route, route point or card.

ACS Noder Implementations

image

Controllers and readers based on Noder family are successfully implemented in the most demanding facilities.
We can provide references for objects from several dozen to over 35,000 users within one centrally managed security system.

NODER EE12

Access Control Ethernet Controller

image

Noder EE12 is 10 doors controller with one-sided access control or 5 doors controller with two-sided access control with monitoring of 4 inputs (e.q. exit button, evacuation button, main evacuation button, magnetic detector for state of door) for each door. Any combination of type of doors possible. Every controller is monitoring 4 inputs constantly (e.q. AC voltage loss at power supply unit, DC voltage loss at output of power supply unit, battery failure, tamper detection).

Controller provides possibily of firmware remote upgrade by integrated management software.

Documentation

DATA SHEET
DECLARATION OF CONFORMITY
MANUAL
on demand

Characteristic

CONTROLLER TYPE
EE12
SUPPORTED PASSING TYPES
10 passes with one-sided access control
or 5 passes with two-sided access control (any combination possible)
NUMBER OF CARDS
1 024 000*
EVENTS MEMORY
2 048 000*
FREQUENCY REPRODUCTION AND PARTITION CONTROL FUNCTION
global AntiPassBack - if connected to the server
local AntiPassBack - in autonomic operating mode
CONTROLLER FIRMWARE UPDATE
Remote



*Values are adequate to the built-in memory of the device

Technical specifications

POWER VOLTAGE
12V DC
CLOCKWORK POWER SUPPLYING DURING POWER LOSS
CR1612/CR1616/CR1620/CR1632 battery
CURRENT CONSUMPTION
350 mA (except readers)
NUMBER OF SERVED READERS
Up to 12
READER'S INTERFACE
Native AES with encapsulation, OSDP
COMPATIBILE READERS
Proximity, biometrics, barcodes, magnetic, OCR, ICR, OMR, UHF
TYPES OF CARD
Compatibile with reader technology
PROGRAMMABLE INPUTS
(magnetic detectors, buttons, alarm detectors, etc.)
20 parametrized inputs
COMMON INPUTS
4 parametrized inputs (AC, BAT, TMP, DR)
PROGRAMMABLE OUTPUTS
(electric latch, tripod, alarm box, etc.)
16 relay outputs NO/NC, 3A 24VDC
IDENTIFICATION MODE
card, PIN, card or PIN, card and PIN
COMMUNICATION WITH READERS
3x RS-485 busses
COMMUNICATION WITH SERVER
ETHERNET
DIMENSIONS
213 x 117 x 28 mm
WEIGHT
350 g
OPERATING TEMPERATURE
-10°C - +55°C
STORAGE TEMPERATURE
-20°C - +70°C
HUMIDITY RELATIVE
Under 80%

NODER EWE4

Access Control Ethernet Controller

image

Noder EWE4 is 4 doors controller with one-sided access control or 2 doors controller with two-sided access control with monitoring of 4 inputs (e.q. exit button, evacuation button, main evacuation button, magnetic detector for state of door) for each door. Any combination of type of doors possible. Every controller is monitoring 4 inputs constantly (e.q. AC voltage loss at power supply unit, DC voltage loss at output of power supply unit, battery failure, tamper detection).

Controller provides possibily of firmware remote upgrade by integrated management software.

Documentation

DATA SHEET
DECLARATION OF CONFORMITY
MANUAL
on demand

Characteristic

CONTROLLER TYPE
EWE4
SUPPORTED PASSING TYPES
4 passes with one-sided access control
or 2 passes with two-sided access control (any combination possible)
NUMBER OF CARDS
1 024 000*
EVENTS MEMORY
2 048 000*
FREQUENCY REPRODUCTION AND PARTITION CONTROL FUNCTION
global AntiPassBack - if connected to the server
local AntiPassBack - in autonomic operating mode
CONTROLLER FIRMWARE UPDATE
Remote



*Values are adequate to the built-in memory of the device

Technical specifications

POWER VOLTAGE
12V DC
CLOCKWORK POWER SUPPLYING DURING POWER LOSS
CR1612/CR1616/CR1620/CR1632 battery
CURRENT CONSUMPTION
200 mA (except readers)
NUMBER OF SERVED READERS
Up to 4 (Wiegand or RS-485)
READER'S INTERFACE
Wiegand or native AES with encapsulation, OSDP
COMPATIBILE READERS
Proximity, biometrics, barcodes, magnetic, OCR, ICR, OMR, UHF
TYPES OF CARD
Compatibility with reader technology
PROGRAMMABLE INPUTS
(magnetic detectors, buttons, alarm detectors, etc.)
16 paramertized inputs
COMMON INPUTS
4 paramertized inputs (AC, BAT, TMP, DR)
PROGRAMMABLE OUTPUTS
(electric latch, tripod, alarm box, etc.)
6 relay outputs NO/NC, 3A 24VDC
IDENTIFICATION MODE
Card, PIN, card or PIN, card and PIN
COMMUNICATION WITH READERS
3x Wiegand or 1x RS-485 busses
COMMUNICATION WITH SERVER
ETHERNET
DIMENSIONS
125 x 130 x 25 mm
WEIGHT
175 g
OPERATING TEMPERATURE
-10°C - +55°C
STORAGE TEMPERATURE
-20°C - +70°C
HUMIDITY RELATIVE
Under 80%

NODER IO16RS

Elevator control extension for controllers

image

IO16RS is an RS-485 extension for Noder's controllers, designed to integrate Noder Access Control System with any types of elevators in building.

Provides easy integration of elevator and manage access to floors for ACS users.

Documentation

DATA SHEET
MANUAL
on demand

Characteristic

TYPE
IO16RS
COMPATIBILE CONTROLLERS
Noder EWE4
Noder EE12
NUMBER OF SUPPORTED FLOORS
16
NUMBER OF EXTENSIONS PER CONTROLLER
1-4
NUMBER OF EXTENSIONS PER ELEVATOR
1-4
NUMBER OF SUPPORTED FLOORS PER SINGLE CONTROLER
1-64



Technical specifications

POWER SUPPLY
12V DC
CURRENT CONSUMPTION
nominal ~200 mA, max ~337mA
MAXIMUM CURRENT PER OUTPUT
1A
NUMBER OF PROGRAMMABLE INPUTS
16
COMMUNICATION WITH CONTROLLER
RS-485
DIMENSIONS
122 x 90 x 23 mm
WEIGHT
300 g
WORKING TEMPERATURE
-10°C - +55°C
STORAGE TEMPERATURE
-20°C - +70°C
AMBIENT RELATIVE HUMIDITY
<80%

Noder MD-R / MD-W

MIFARE Classic / DESFire Reader

image

The solution dedicated to access control systems requiring the highest level of security. Made of durable polycarbonate the reading housing maintains a uniform design for the entire series of products. The device cooperates with any access control system using RS-485 or Wiegand data transmission standard through a dedicated protocol. DESFire is a modernized in relation to MIFARE a better secured transmission between the reader and the transponder. The DESFire support used in the device is fully compilant with the older MIFARE standard (including sector readings) and has the ability to read CSN numbers from MIFARE DESFire Cards. To ensure maximum security of access control system for each end-user individual transmission keys are generated.

The device works with a specialized program that allows you to create your own security policy for readers and cards including: credential profiles, formats, unique identifiers and configuration of readers through programming cards. The programming system of transponders / cards / ID tags and readers is intented for issuing and personalizing proximity transponders and dedicated RFID readers. The advanced program allows you to manage custom configurations and create individual reader settings.

Interface RF: ISO/IEC 14443 TYPE A
Accordance with ISO/IEC 7816

SECURITY

  • certyficate EAL4 + (hardware and software);
  • unique serial number;
  • optional, random ID to increase;
  • security and privacy;
  • muthal three-step authorization;
  • authorization in accordance with ISO/IEC7816-4;
  • 1 master key for card and 14 keys for application;
  • encryption AES;
  • encryption DES;
  • data encryption between card and reader;
  • application level authentication;
  • hardware ‘watchdog’;
  • secure file system;
  • backward compatibility:
  • MF3ICD40: 4 byte MAC, CRC 16;

Documentation

DATA SHEET
MANUAL
on demand

Technical specifications

POWER VOLTAGE
10-15V DC
CURRENT CONSUMPTION
~85 mA (max. 105mA)
COMMUNICATION INTERFACE
MD-R - RS-485 (own encryption or AES-256)
MD-W - Wiegand
MAXIMUM DISTANCE FROM THE CONTROLLER
Up to 4cm
COMPATIBILITY
MIFARE Classic/DESFire
TYPES OF CARD
MIFARE Classic/DESFire
OPERATING MODE
Read only
WORKING FREQUENCY
13,56MHz
MAXIMUM DISTANCE FROM THE CONTROLLER
MD-R 1000m (except power),
MD-W - 50m
INDICATORS
two-color LED diode, buzzer
SECURITY LEVEL
IP65
COLOR
Black
DATA CONNECTOR
Pigtail
DIMENSIONS
40 x 90 x 16 mm
WEIGHT
85 g
OPERATING TEMPERATURE
-40°C - +65°C
STORAGE TEMPERATURE
-50°C - +80°C
HUMIDITY RELATIVE
Under 80%

Noder MDK-R

MIFARE DESFire Reader with keypad

image

Documentation

DATA SHEET
MANUAL
on demand

Technical specifications

POWER VOLTAGE
10-15V DC
CURRENT CONSUMPTION
~100 mA (max. 130mA)
COMMUNICATION INTERFACE
RS-485
MAXIMUM DISTANCE FROM THE CONTROLLER
Up to 4cm
COMPATIBILITY
MIFARE DESFire
TYPES OF CARD
MIFARE DESFire
OPERATING MODE
read only
WORKING FREQUENCY
13,56MHz
MAXIMUM DISTANCE FROM THE CONTROLLER
1000m (except power)
INDICATORS
two-color LED diode, buzzer
SECURITY LEVEL
IP51
COLOR
Black
DATA CONNECTOR
Pigtail
DIMENSIONS
75 x 115 x 16 mm
WEIGHT
100 g
OPERATING TEMPERATURE
-40°C - +65°C
STORAGE TEMPERATURE
-50°C - +80°C
HUMIDITY RELATIVE
Under 80%


Noder MD-USB

MIFARE DESFire Desk Reader

image

Documentation

DATA SHEET
MANUAL
on demand

Technical specifications

POWER VOLTAGE
5V from USB port
COMMUNICATION INTERFACE
USB (Serial port emulation)
MAXIMUM DISTANCE FROM THE CONTROLLER
Up to 8cm
COMPATIBILITY
MIFARE DESFire
TYPES OF CARD
MIFARE DESFire
OPERATING MODE
read only
WORKING FREQUENCY
13,56MHz
INDICATORS
two-color LED diode, buzzer
SECURITY LEVEL
IP44
COLOR
Black
DATA CONNECTOR
USB
DIMENSIONS
80 x 110 x 25 mm
WEIGHT
105 g
OPERATING TEMPERATURE
-40°C - +65°C
STORAGE TEMPERATURE
-50°C - +80°C
HUMIDITY RELATIVE
Under 80%


Reader/Programmer RFID
(MIFARE/DESFire/Bluetooth)

image

The solution dedicated to access controll systems requiring the highest degree of security. Made of durable polycarbonate the reading housing maintains a uniform design for the entire series of products. The device cooperates with any access control system using data transmission in the Wiegand standard. DESFire is a modernized in relation to MIFARE a better secured transmission between the reader and the transponder (card or key ring). Novelty used in the device is support for Bluetooth and NFC credentials as well as typical reader standards – data output in the form of WIEGAND, support for the latest DESFire cards while complying with the older MIFARE standard (including sector readings) and the ability to read CSN numbers from MIFARE/DESFire cards. To ensure maximum security of access control system for each final client individual transmission keys are generated. The reader is equipped with two optical anti-tamper sensors signaling the opening of the cover and detaching from the wall.

The use of Bluetooth 4.0 technology allows the device to be used in various business areas, in particular related to logistic and fast registration of goods. The reader in combination with BT4.0 tags of various sizes and shapes, allows detection of the presence of these tags in the reading range. It allows transfering more data than commonly used cards, measuring the strength of the received signal from the bitcoin tag and smoothly adjusting the power emitted by the reader. These features allow for high flexibility of this technology for specific use of location functions of tags based on triangulation – including the possibility of implementation by third parties and integrators.

Technical specification

POWER VOLTAGE
5-16V DC
CURRENT CONSUMPTION
~85 mA (max. 105 mA)
COMMUNICATION INTERFACE
RS-485 or Wiegand
MAXIMUM DISTANCE FROM THE CONTROLLER
Up to 8 cm for MIFARE DESFire cards, up to 10m for Bluetooth
COMPATIBILITY
MIFARE/DESFire
TYPES OF CARD
MIFARE Classic, DESFire, cards emulated in smartphones
OPERATING MODE
Reading / programming MIFARE/DESFire
WORKING FREQUENCY
13,56MHz + Bluetooth 4.0 BLE
MAXIMUM DISTANCE FROM THE CONTROLLER
500m for RS-485, 50m for Wiegand
INDICATORS
3-color diode LED, buzzler
SECURITY LEVEL
IP65
COLOR
Grey
DATA CONNECTOR
Screw terminal / pigtail
DIMENSIONS
70 x 123 x 21 mm
WEIGHT
105 g
OPERATING TEMPERATURE
-40°C - +65°C
STORAGE TEMPERATURE
-50°C - +80°C
HUMIDITY RELATIVE
Under 80%
OTHER FEATURES
Optical temper, accelerometer

CONTACT

image

Manufacturer:

Nuuxe Radioton Sp. z o.o.

Olszańska 5H street

31-513 Cracow, Poland

nuuxe@nuuxe.com

Do you have any questions? Contact us, we will be happy to advise you.